|
sane-coolscan(5)
Contents
|
sane-coolscan - SANE backend for Nikon film-scanners
This file is a short descripton of the coolscan-backend for sane!
The sane-coolscan library implements a SANE backend that provides the
interface to the following Nikon Coolscan Film scanners: Nikon LS20,
LS30, LS1000, LS2000.
Even though the backend has worked for a number of people, there are
still some problems, especially in combination with some SCSI
card/drivers (AHA-1505/aha152x.o) and the autofocus command. You should
consider this backend 'alpha' and be carefull when using it the first
time.
The configuration file for this backend resides in
/etc/sane.d/coolscan.conf.
Its contents is a list of device names that correspond to Nikon
Coolscan scanners. Empty lines and lines starting with a hash mark (#)
are ignored. A sample configuration file is shown below:
#scsi Vendor Model Type
scsi Nikon * Scanner
/dev/scanner
The special device name must be a generic SCSI device or a symlink to
such a device. To find out to which device your scanner is assigned
and how you have to set the permissions of that device, have a look at
sane-scsi.
Some SCSI-adapters and low-level SCSI drivers do not work correctly
with this backend and the Coolscan scanners. These systems hang when
the autofocus command is send to the Scanner. To see a list of which
card/driver combinations work or dont work have a look at:
http://andreas.rick.free.fr/sane/autofocus.html.
The backend configuration file:
/etc/sane.d/coolscan.conf.
The static library implementing this backend:
/usr/lib/sane/libsane-coolscan.a
The shared library implementing this backend:
/usr/lib/sane/libsane-coolscan.so
(present on systems that support dynamic loading)
SANE_DEBUG_COOLSCAN
If the library was compiled with debug support enabled, this environment
variable controls the debug level for this backend. E.g., a value
of 128 requests all debug output to be printed. Smaller levels reduce
verbosity: SANE_DEBUG_COOLSCAN values
Examples:
on bash:
export SANE_DEBUG_COOLSCAN=8
on csh
setenv SANE_DEBUG_COOLSCAN 8
The autofocus command does not work with some SCSI card/driver combinations
The gamma table is not implemented for the LS1000 yet.
The dust-removal is not working yet
http://andreas.rick.free.fr/sane/ The homepage of this backend
http://www.sema.be/coolscan/ The original version of the coolscan
backend by Didier
sane(7), sane-scsi(5)
Didier Carlier - For writing the original Coolscan backend (without it
I would not have started this)
Oliver.Rauch - For adapting xsane so quickly to the infrared stuff.
All the other people working on SANE.
Andreas Rick
[email protected]
4 July 2000 sane-coolscan(5)
[ Back ] |