NAME    [Toc]    [Back]

     pciconf -- diagnostic utility for the PCI bus

SYNOPSIS    [Toc]    [Back]

     pciconf -l [-v]
     pciconf -a selector
     pciconf -r [-b | -h] selector addr[:addr2]
     pciconf -w [-b | -h] selector addr value

DESCRIPTION    [Toc]    [Back]

     The pciconf utility provides a command line interface to functionality
     provided by the pci(4) ioctl(2) interface.  As such, it is only available
     to users with write access to /dev/pci, normally only the super-user.

     With the -l option, it lists all devices found by the boot probe in the
     following format:

     foo0@pci0:4:0: class=0x010000 card=0x00000000 chip=0x000f1000 rev=0x01 hdr=0x00
     bar0@pci0:5:0: class=0x000100 card=0x00000000 chip=0x88c15333 rev=0x00 hdr=0x00
     none0@pci0:6:0: class=0x020000 card=0x00000000 chip=0x802910ec rev=0x00 hdr=0x00

     If the -v option is supplied, pciconf will attempt to load the vendor/device
 information database, and print vendor, device, class and subclass
 identification strings for each device.

     The first column gives the device name, unit number, and selector.  If
     there is no device configured in the kernel for the PCI device in question,
 the device name will be ``none''.  Unit numbers for unconfigured
     devices start at zero and are incremented for each unconfigured device
     that is encountered.  The selector is in a form which may directly be
     used for the other forms of the command.  The second column is the class
     code, with the class byte printed as two hex digits, followed by the subclass
 and the interface bytes.  The third column gives the contents of
     the subvendorid register, introduced in revision 2.1 of the PCI standard.
     It is 0 for most current (2.0) PCI cards, but is supposed to be loaded
     with a unique card identification code in newly developed PCI cards.  The
     field consists of the card ID in the upper half and the card vendor ID in
     the lower half of the value.

     The fourth column contains the chip device ID, which identifies the chip
     this card is based on.  It consists of two fields, identifying the chip
     and its vendor, as above.	The fifth column prints the chip's revision.
     The sixth column describes the header type.  Currently assigned header
     types are 0 for all devices except PCI to PCI bridges, and 1 for such
     bridge chips.  If the most significant bit of the header type register is
     set for function 0 of a PCI device, it is a multi-function device, which
     contains several (similar or independent) functions on one chip.

     All invocations of pciconf except for -l require a selector of the form
     pcibus:device (optionally followed by :function).	A final colon may be
     appended and will be ignored; this is so that the first column in the
     output of pciconf -l can be used without modification.  All numbers are
     base 10.

     With the -a flag, pciconf determines whether any driver has been assigned
     to the device identified by selector.  An exit status of zero indicates
     that the device has a driver; non-zero indicates that it does not.

     The -r option reads a configuration space register at byte offset addr of
     device selector and prints out its value in hexadecimal.  The optional
     second address addr2 specifies a range to read.  The -w option writes the
     value into a configuration space register at byte offset addr of device
     selector.	For both operations, the flags -b and -h select the width of
     the operation; -b indicates a byte operation, and -h indicates a halfword
     (two-byte) operation.  The default is to read or write a longword (four
     bytes).

ENVIRONMENT    [Toc]    [Back]

     The PCI vendor/device information database is normally read from
     /usr/share/misc/pci_vendors.  This path can be overridden by setting the
     environment variable PCICONF_VENDOR_DATABASE.

SEE ALSO    [Toc]    [Back]

      
      
     ioctl(2), kldload(8)

HISTORY    [Toc]    [Back]

     The pciconf utility appeared first in FreeBSD 2.2.  The -a option was
     added for PCI KLD support in FreeBSD 3.0.

AUTHORS    [Toc]    [Back]

     The pciconf utility was written by Stefan Esser and Garrett Wollman.

BUGS    [Toc]    [Back]

     The -b and -h options are implemented in pciconf, but not in the underlying
 ioctl(2).

     It might be useful to give non-root users access to the -a and -r
     options.  But only root will be able to execute a kldload to provide the
     device with a driver KLD, and reading of configuration space registers
     may cause a failure in badly designed PCI chips.


FreeBSD 5.2.1		       February 7, 1997 		 FreeBSD 5.2.1
[ Back ]
 Similar pages
Name OS Title
mptutil HP-UX Diagnostic utility for Ultra320 SCSI controllers and A7173A
dlerror Tru64 get diagnostic information
dlerror IRIX get diagnostic information
diag1 HP-UX diagnostic interface to the PCI I/O subsystem
lmdiag IRIX diagnostic checkout tool
diag0 HP-UX diagnostic interface to HP-PB I/O subsystem
egcmd IRIX gigabit ethernet diagnostic tool
ipxdebug IRIX enable or disable diagnostic output from IPX
fmtmsg FreeBSD display a detailed diagnostic message
crashdc Tru64 Diagnostic data collection for a running or crashed system
Copyright © 2004-2005 DeniX Solutions SRL
newsletter delivery service